RECOMMENDED FOR: Hot and cold water high–pressure cleaning equipment where heavy–duty service is required. Specially compounded
cover to handle pressure washer environment.
CAUTION: Not recommended for steam service. Use bend restrictors to extend service life.
TEMPERATURE: –40°F to +250°F (–40°C to +121°C). Laboratory tested for normal service. Increased operating temperatures will
reduce hose assembly service life.
CONSTRUCTION: Tube: Type C (Nitrile). Black.
Reinforcement: Braided, high tensile steel wire.
Cover: | Type C2 (Modified Nitrile). Non–marking except for black. |
74 Gates MegaCrimp® couplings. Reference the Hose COUPLINGS: Coupling Section. | |
STANDARDS: Exceeds EN1829–2 |